This product has been replaced by

Kidde-Fenwal 28021-5 600°F

Fire / Overheat Detector, Vertical, Coupling Head, Normally Open, 600°F

Manufacturer Part #: 28021-5-600

Kidde-Fenwal 28021-5 600°F

$392.00

Fire / Overheat Detector, Vertical, Coupling Head, Normally Open, 600°F

Availability: Estimated 6 days
Condition: New
Brand: Kidde-Fenwal
Status: Active
SKU: 62077
Manufacturer Part #: 28021-5-600
Secondary Part #: 12-H28021-005 600F

Description

DETECT-A-FIRE® (D-A-F) detectors are the "heart" of many fire protection systems. The highly reliable D-A-F has been the standard for over 75 years. The D-A-F is used for signaling overheat or fire conditions. In the vast majority of applications, the D-A-F provides the initial heat sensing that is used to activate suppression systems using clean agent, CO2, inert gases, wet or dry chemicals or water. D-A-F detectors are widely accepted, because they are designed with rate compensation. This provides a unique advantage over both fixed temperature and rate-of-rise types of detectors because the D-A-F detector accurately senses the surrounding air temperature regardless of the fire growth rate. At the pre-determined set point, the system is activated.

Documents

Description

DETECT-A-FIRE® (D-A-F) detectors are the “heart” of many fire protection systems. The highly reliable D-A-F has been the standard for over 75 years. The D-A-F is used for signaling overheat or fire conditions. In the vast majority of applications, the D-A-F provides the initial heat sensing that is used to activate suppression systems using clean agent, CO2, inert gases, wet or dry chemicals or water. D-A-F detectors are widely accepted, because they are designed with rate compensation. This provides a unique advantage over both fixed temperature and rate-of-rise types of detectors because the D-A-F detector accurately senses the surrounding air temperature regardless of the fire growth rate. At the pre-determined set point, the system is activated.

Additional information

Weight 0.2 lbs
Manufacturer

Carrier

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Contact Configuration

Normally Open

Detectable Medium

Heat

Detection Method

Fixed Temperature, Rate Compensation

Location

Hazardous, Indoor, Outdoor

Mounting

Vertical

Thermal Rating

600°F

Series

Reviews

There are no reviews yet.

Be the first to review “Kidde-Fenwal 28021-5 600°F”

DETECT-A-FIRE; Detection and Release Devices

Download

Fenwal Controls - Data Sheet

Series 27100, 28000; Vertical DETECT-A-FIRE Units

Download

Fenwal Controls - Installation Instructions

Attributes

Weight 0.2 lbs
Manufacturer

Carrier

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Contact Configuration

Normally Open

Detectable Medium

Heat

Detection Method

Fixed Temperature, Rate Compensation

Location

Hazardous, Indoor, Outdoor

Mounting

Vertical

Thermal Rating

600°F

Series

Product Features

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Kidde-Fenwal 28021-5 600°F”

You may also like...

Explosion Proof Junction Box
Mfr. Part #: 06-116317-001
SKU: 10297

$429.24

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/