This product has been replaced by

Kidde-Fenwal 84-70101793

Kidde AEGIS-XLT Control Unit Red NEMA 1 Enclosure

Manufacturer Part #: 84-70101793

Kidde-Fenwal 84-70101793

$1,664.04

Kidde AEGIS-XLT Control Unit Red NEMA 1 Enclosure

Availability: Estimated 12 days
Condition: New
Brand: Kidde-Fenwal
Status: Active
SKU: 159875
Manufacturer Part #: 84-70101793

Description

The AEGIS-XLT Control Unit is listed for use with a wide range of suppression systems and can be used to control Kidde Fire Systems’ ECS™ and ADS™ Clean Agents, HP CO2, LP CO2, WHDR™ Wet Chemical and IND™ Dry Chemical systems as well as FENWAL® Initiators, Chemetron® release equipment, sprinkler supervisory, deluge/pre-action, foam and foam/water systems. With its large range of configuration options and settings, NEMA 1, NEMA 4 and NEMA 12 enclosures, the AEGIS-XLT Control Unit is ideal for LP CO2, Watermist and Spurt applications protecting assets in industrial, manufacturing, high-tech and commercial environments. Supports Low Pressure CO2, watermist and SPURT applications in addition to Clean Agent and High Pressure CO2 applications. Two (2) In-Line Releasing-Circuit Devices (06-220023-001) are included, order additional devices as needed. Replaces Chemetron 70101533 and 70101793. Not compatible with Gateway P/N 77-100000-002.

Documents

Description

The AEGIS-XLT Control Unit is listed for use with a wide range of suppression systems and can be used to control Kidde Fire Systems’ ECS™ and ADS™ Clean Agents, HP CO2, LP CO2, WHDR™ Wet Chemical and IND™ Dry Chemical systems as well as FENWAL® Initiators, Chemetron® release equipment, sprinkler supervisory, deluge/pre-action, foam and foam/water systems.

With its large range of configuration options and settings, NEMA 1, NEMA 4 and NEMA 12 enclosures, the AEGIS-XLT Control Unit is ideal for LP CO2, Watermist and Spurt applications protecting assets in industrial, manufacturing, high-tech and commercial environments.

Supports Low Pressure CO2, watermist and SPURT applications in addition to Clean Agent and High Pressure CO2 applications. Two (2) In-Line Releasing-Circuit Devices (06-220023-001) are included, order additional devices as needed. Replaces Chemetron 70101533 and 70101793. Not compatible with Gateway P/N 77-100000-002.

Additional information

Weight 16 lbs
Dimensions 14.25 × 5.00 × 19.00 in
Manufacturer

UTC Fire & Security

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

AEGIS-XLT Conventional Fire Alarm-Suppression Control Unit

Download

Kidde - Data Sheet

New York City Fire Department; Certificate of Approval

Download

Kidde - Certificate of Approval

AEGIS™-XLT Suppression Control Units

Download

Kidde - Brochure

Attributes

Weight 16 lbs
Dimensions 14.25 × 5.00 × 19.00 in
Manufacturer

UTC Fire & Security

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

  • NEMA 1, 4 and 12 enclosures
  • Triple-R™ redundancy safeguards the system from inadvertent suppression activation
  • Flexible programming with large range of release on and pre-discharge time settings
  • Spurt Mode
  • Water Mist and Thermal Cycling Operation
  • 3 Detection Circuits
  • Option to configure SUP 1 as 4th detection circuit for contact closure devices
  • Two independently programmable Agent Releasing Circuits
  • Three sophisticated programmable Notification Appliance Circuits
  • Option to configure NAC 1 as 3rd Release Circuit
  • 4 Amp Power Supply Unit
  • Listed for use with Kidde®, FENWAL® and Chemetron® agent release devices

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/