Notifier FSP-951T-SELFT-BP

$1,313.20

Self-Test Intelligent Addressable Photo/Thermal Detector with FlashScan – White. Compatible only with the new N16 panel. Bulk pack of 10.

Availability: Please Call for Availability
Condition: New
Brand: Notifier
Status: Active
SKU: 202177
Manufacturer Part #: FSP-951T-SELFT-BP
Note: Bulk pack of 10.

Description

The breakthrough NOTIFIER Self-Test Series intelligent plug-in smoke detectors are designed for performance, ease of use, and aesthetics. When used with the NOTIFIER INSPIRE Series N16 panel and initiated through an app, the Self-Test Series detectors automatically perform maintenance tests of smoke and heat detection without using canned smoke or heat guns. The Self-Test process meets the three core NFPA requirements for detector maintenance: functional test, smoke entry test, and ability to verify a visual inspection has taken place. It is the first detector of its type to be approved by UL. It also retains the great features of the standard 951 series including the enhanced optical sensing chamber which is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. For ease, its sensitivity can also be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel for selective maintenance when chamber contamination reaches an unacceptable level.

Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951T-SELFT. The FST-951-SELFT intelligent temperature sensor can be programmed as either a 135°F fixed temperature sensor, a rate of rise and 135°F fixed temperature sensor, or a 190°F high-temperature sensor through the Fire Alarm Control Panel (FACP).

Point ID capability allows each detector’s address to be set with rotary, decimal address switches providing exact detector location. The NOTIFIER Self-Test series detectors are available for our FlashScan applications.

Documents

Description

The breakthrough NOTIFIER Self-Test Series intelligent plug-in smoke detectors are designed for performance, ease of use, and aesthetics. When used with the NOTIFIER INSPIRE Series N16 panel and initiated through an app, the Self-Test Series detectors automatically perform maintenance tests of smoke and heat detection without using canned smoke or heat guns. The Self-Test process meets the three core NFPA requirements for detector maintenance: functional test, smoke entry test, and ability to verify a visual inspection has taken place. It is the first detector of its type to be approved by UL. It also retains the great features of the standard 951 series including the enhanced optical sensing chamber which is engineered to sense smoke produced by a wide range of combustion sources in accordance with more stringent code standards. For ease, its sensitivity can also be programmed in the control panel software. Sensitivity is continuously monitored and reported to the panel for selective maintenance when chamber contamination reaches an unacceptable level.

Dual electronic thermistors add 135°F (57°C) fixed temperature thermal sensing on the FSP-951T-SELFT. The FST-951-SELFT intelligent temperature sensor can be programmed as either a 135°F fixed temperature sensor, a rate of rise and 135°F fixed temperature sensor, or a 190°F high-temperature sensor through the Fire Alarm Control Panel (FACP).

Point ID capability allows each detector’s address to be set with rotary, decimal address switches providing exact detector location. The NOTIFIER Self-Test series detectors are available for our FlashScan applications.

Additional information

Weight 2.5 lbs
Dimensions 14 × 10 × 6 in
Manufacturer

Honeywell

Brand

Condition

New

Unit of Measurement

PK (Pack)

Production Status

Active

Self-Test Series Self-Testing Addressable Detectors

Download

Notifier - Data Sheet

Attributes

Weight 2.5 lbs
Dimensions 14 × 10 × 6 in
Manufacturer

Honeywell

Brand

Condition

New

Unit of Measurement

PK (Pack)

Production Status

Active

Product Features

  • Introduces small amounts of smoke and heat into the chamber to test both sensors
  • Automatically tests if the photo sensor smoke entry points are blocked by the dust cover
  • Verifies that the technician has completed the visual inspection through its built-in beacon and the self test app
  • Tests detectors across multiple loops and panels concurrently
  • Listed to UL 268 7th edition and/or UL 521

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/