Notifier LDM-32 – Used

$200.00

Lamp Driver Module with 32 Alarm Lamp-driver Transistors

Availability: In Stock
Condition: Used
Brand: Notifier
Status: Active
SKU: 62945
Manufacturer Part #: LDM-32
Note: Photos available upon request.

Description

The LDM Series lamp driver modules, when combined with a custom graphic display, provide annunciation and control for Fire Lite’s intelligent fire alarm control panels. These modules use a serial communications interface, and may be located up to 6,000 feet from the panel. The Lamp Driver Module LDM-32F has 32 alarm lamp/LED driver outputs which sink current to system common (–) on activation. A single positive (+) voltage is required to supply total operating power for all lamps or LEDs when all drivers are activated. The LDM-32F provides a separate driver for system trouble and inputs for a local lamp test switch. A maximum of 16 external control switches may be wired to the LDM-32F. DIP switch SW3 is used to enable or disable the on board piezo, enable remote switch functions, select a flashing LED function for new alarms and troubles, and other functions. Switch SW4 is used to configure the module to annunciate 32 alarms or 16 troubles. A green ON LINE LED flashes to indicate ongoing communications with the host FACP. One LDM-32F supports up to 3 LDM-E32F modules. The LDM-32F is supplied with 4 standoffs and screws for mounting to a CHS-4L chassis or custom back box.

Documents

Description

The LDM Series lamp driver modules, when combined with a custom graphic display, provide annunciation and control for Fire Lite’s intelligent fire alarm control panels. These modules use a serial communications interface, and may be located up to 6,000 feet from the panel. The Lamp Driver Module LDM-32F has 32 alarm lamp/LED driver outputs which sink current to system common (–) on activation. A single positive (+) voltage is required to supply total operating power for all lamps or LEDs when all drivers are activated. The LDM-32F provides a separate driver for system trouble and inputs for a local lamp test switch. A maximum of 16 external control switches may be wired to the LDM-32F. DIP switch SW3 is used to enable or disable the on board piezo, enable remote switch functions, select a flashing LED function for new alarms and troubles, and other functions. Switch SW4 is used to configure the module to annunciate 32 alarms or 16 troubles. A green ON LINE LED flashes to indicate ongoing communications with the host FACP. One LDM-32F supports up to 3 LDM-E32F modules. The LDM-32F is supplied with 4 standoffs and screws for mounting to a CHS-4L chassis or custom back box.

Additional information

Weight 1 lbs
Dimensions 10.00 × 8.50 × 3.50 in
Manufacturer

Honeywell

Unit of Measurement

EA (Each)

Brand

Condition

Used

Type

Option Card

Style

Driver Module

Production Status

Active

Listings & Approvals

City of Chicago, City of Denver, FM, MEA, UL, ULC

Reviews

There are no reviews yet.

Be the first to review “Notifier LDM-32 – Used”

Lamp Driver Module

Download

Notifier - Data Sheet

Attributes

Weight 1 lbs
Dimensions 10.00 × 8.50 × 3.50 in
Manufacturer

Honeywell

Unit of Measurement

EA (Each)

Brand

Condition

Used

Type

Option Card

Style

Driver Module

Production Status

Active

Listings & Approvals

City of Chicago, City of Denver, FM, MEA, UL, ULC

Product Features

  • ALARM/CIRCUIT ON and TROUBLE lamp/LED per-point option, or more dense alarm-only option (field selectable).
  • Control switch option for remote control per point.
  • Lamps/LEDs may be programmed to display status of indicating circuits or control relays as well as system status conditions.
  • System trouble lamp/LED signal.
  • On-line/power LED indicator.
  • Alarm and trouble resound with flash of new conditions.
  • Local sounder for both alarm/circuit-on and trouble conditions with silence/acknowledge switch connection.
  • Serial EIA-485 interface for reduced installation costs.
  • May be powered by 24 VDC from the panel or by remote power supplies.
  • Efficient switch-power converter reduces power consumption.
  • Microprocessor-controlled electronics, fully supervised.
  • Plug-in terminal blocks for ease of installation and service.
  • Trouble monitor option for remote power supplies.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Notifier LDM-32 – Used”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/