Description

The Wireless Setup Tool, model WST, is required for installation. See document #5401608 for more information regarding the setup tool. The tool is used to check signal strength between all devices among other features. It is strongly recommended a site survey be conducted before installing the wireless system. Failure to conduct a thorough site survey may result in communication errors later. The installer should determine where the transmitter will be located. The receiver shall be mounted adjacent to the fire panel. Typically, higher on a wall allows the receiver to “see” over obstructions and provides a better path for the wireless signal. Keep in mind that the metal framing of a drop ceiling can affect the signal. The receiver should not be installed near a large metal object as that could attenuate the signal. After identifying the location of the transmitter and receiver the installer should walk around and in between the areas where the transmitter and receiver will be installed and look for possible obstructions to the wireless signal such as metal fences, metal doors, wired glass and other metal objects. The installer should investigate to determine if the normal business processes throughout the day might result in an obstruction between the transmitter and receiver. Possible obstructions could include the movement of equipment or fork trucks, traffic patterns for shipping, deliveries, trash pickup, food trucks, etc.

Documents

Description

The Wireless Setup Tool, model WST, is required for installation. See document #5401608 for more information regarding the setup tool. The tool is used to check signal strength between all devices among other features. It is strongly recommended a site survey be conducted before installing the wireless system. Failure to conduct a thorough site survey may result in communication errors later. The installer should determine where the transmitter will be located. The receiver shall be mounted adjacent to the fire panel. Typically, higher on a wall allows the receiver to “see” over obstructions and provides a better path for the wireless signal. Keep in mind that the metal framing of a drop ceiling can affect the signal. The receiver should not be installed near a large metal object as that could attenuate the signal. After identifying the location of the transmitter and receiver the installer should walk around and in between the areas where the transmitter and receiver will be installed and look for possible obstructions to the wireless signal such as metal fences, metal doors, wired glass and other metal objects. The installer should investigate to determine if the normal business processes throughout the day might result in an obstruction between the transmitter and receiver. Possible obstructions could include the movement of equipment or fork trucks, traffic patterns for shipping, deliveries, trash pickup, food trucks, etc.

Additional information

Weight 1 lbs
Manufacturer

Potter Electric Signal Company, LLC

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

SignaLink™ Bridge; Wireless Supervisory System

Download

Potter - Data Sheet

Attributes

Weight 1 lbs
Manufacturer

Potter Electric Signal Company, LLC

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/