This product has been replaced by

Protectowire CTM-530E-I

Interface Module with ISB for Protectowire Type CTI with LCD display and navigation buttons mounted in a NEMA-4X (IP66) Enclosure

Manufacturer Part #: CTM-530E-I

Protectowire CTM-530E-I

$1,154.69

Interface Module with ISB for Protectowire Type CTI with LCD display and navigation buttons mounted in a NEMA-4X (IP66) Enclosure

Availability: Estimated 30 days
Condition: New
Brand: Protectowire
Status: Active
SKU: 126922
Manufacturer Part #: CTM-530E-I

Description

The CTM-530 is a detection control module that acts as an interface between a main fire alarm control panel detection circuit or addressable node and Protectowire Type CTI Linear Heat Detector. The module provides one (1) supervised detection circuit that may be field wired for either Class A (Style D) or Class B (Style B) service. The alarm initiating circuit is capable of operating up to 4000 feet (1220 meters)* of Protectowire Type CTI Linear Heat Detector. The CTM-530 initiating circuit currently does not support other types of normally open contact alarm initiating devices.

Documents

Description

The CTM-530 is a detection control module that acts as an interface between a main fire alarm control panel detection circuit or addressable node and Protectowire Type CTI Linear Heat Detector. The module provides one (1) supervised detection circuit that may be field wired for either Class A (Style D) or Class B (Style B) service. The alarm initiating circuit is capable of operating up to 4000 feet (1220 meters)* of Protectowire Type CTI Linear Heat Detector. The CTM-530 initiating circuit currently does not support other types of normally open contact alarm initiating devices.

Additional information

Weight 1 lbs
Dimensions 10.50 × 8.50 × 4.50 in
Manufacturer

The Protectowire Company

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Model

CTM

CTM-530 Series Protectowire Interface Module with Confirmed Temperature Initiation (CTI™)

Download

Protectowire - Data Sheet

Attributes

Weight 1 lbs
Dimensions 10.50 × 8.50 × 4.50 in
Manufacturer

The Protectowire Company

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Model

CTM

Product Features

  • Temperature verification and short circuit discrimination
  • Engineered and designed for use with suppression systems
  • MUST be connected to a CTI Linear Heat Detector
  • Integrated Protectowire Alarm Point Location Meter with field calibration
  • CTM-530 control module can support up to 4,000 feet (1,220 meters) of CTI Linear Heat Detector per zone
  • Modbus over RS-485 communications
  • 4-20 mA outputs for status and alarm point location
  • 64 event history log (FIFO)
  • 4×20 LED backlit LCD display
  • Approved for use in hazardous locations

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/