Description

The PIM-530 is a detection control module that acts as an inter-face between a main fire alarm control panel detection circuit or addressable node and Protectowire Digital Linear Heat Detector. The module provides one (1) supervised detection circuit that may be field wired for either Class A (Style D) or Class B (Style B) service. The alarm initiating circuit is capable of operating up to 6560 feet (2000 meters) of Standard PHSC or PLR Digital Type Protectowire Linear Heat Detectors. The PIM-530 initiating circuit is also compatible with other types of non-resistive normally open contact alarm initiating devices.

Documents

Description

The PIM-530 is a detection control module that acts as an inter-face between a main fire alarm control panel detection circuit or addressable node and Protectowire Digital Linear Heat Detector. The module provides one (1) supervised detection circuit that may be field wired for either Class A (Style D) or Class B (Style B) service. The alarm initiating circuit is capable of operating up to 6560 feet (2000 meters) of Standard PHSC or PLR Digital Type Protectowire Linear Heat Detectors. The PIM-530 initiating circuit is also compatible with other types of non-resistive normally open contact alarm initiating devices.

Additional information

Weight 0.2 lbs
Dimensions 8.00 × 1.50 × 6.00 in
Manufacturer

The Protectowire Company

Brand

Condition

New

Unit of Measurement

EA (Each)

Model

PIM

Production Status

Discontinued

Reviews

There are no reviews yet.

Be the first to review “Protectowire PIM-530E”

PIM-530 Series; Protectowire Linear Heat Detector Interface Module

Download

Protectowire - Data Sheet

Attributes

Weight 0.2 lbs
Dimensions 8.00 × 1.50 × 6.00 in
Manufacturer

The Protectowire Company

Brand

Condition

New

Unit of Measurement

EA (Each)

Model

PIM

Production Status

Discontinued

Product Features

  • Provides a single zone interface for Protectowire Digital
  • Linear Heat Detectors
  • Capable of Class A (Style D) or Class B (Style B monitoring of up to 6560 Feet (2000 Meters) of Protectowire Linear Heat Detector
  • Integrated Protectowire Alarm Point Location Meter with “on-screen” field calibration
  • 64 Event History Log (FIFO)
  • 4×20 LED backlit LCD display
  • Individual Power, Alarm and Fault indicators
  • Modbus over RS-485 communications
  • 4-20mA outputs for Status and Alarm Point Location
  • Optional intrinsically safe detection circuit available for use in hazardous locations.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Protectowire PIM-530E”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/