Reliable BW208732S9

$476.36

Sprinkler WP56, 200°F, Pendent, 1/2″ NPT, Poly White

Availability: Please Call for Availability
Condition: New
Brand: Reliable
Status: Active
SKU: 209903
Manufacturer Part #: BW208732S9
Secondary Part #: WP562W

Description

Reliable Model WP Series Window Protection Sprinklers are fast response, pendent vertical sidewall, specific application sprinklers designed to provide complete coverage and wetting of heat strengthened, tempered, or ceramic glass windows.

These sprinklers were tested and listed by Underwriters Laboratories for their ability to maintain the integrity of a window assembly placed in a test furnace for a 2-hour period. The test is based upon gas flow into the furnace as required to achieve a temperature in the furnace in the absence of sprinklers matching the standard time-temperature curve in ASTM E119.

Where approved in accordance with Sections 104 of the International Building Code and International Fire Code, which in part authorizes the use of alternative materials and methods, Model WP Series Window Sprinklers may be used as interior protection of non-operable windows or glazing that are part of a fire resistance rated wall in sprinklered or non-sprinklered buildings. With the thermal operating elements removed, some of these sprinklers may also be used for outdoor exposure protection of non-operable windows or glazing when installed on a deluge system in accordance with NFPA requirements.

Model WP Series Window Protection Sprinklers are available in a variety of finishes (see Table F). Model WP56 sprinklers in white polyester, black polyester, or Electroless Nickel PTFE (ENT) finishes are cULus Listed as corrosion resistant sprinklers. The Model WP56SS (Stainless Steel) is cULus listed as corrosion resistant without any additional finish, but may be polyester coated for aesthetic reasons. In addition to the exposed versions of the product, the Model WP56C offers a flat plate concealed option.

Documents

Description

Reliable Model WP Series Window Protection Sprinklers are fast response, pendent vertical sidewall, specific application sprinklers designed to provide complete coverage and wetting of heat strengthened, tempered, or ceramic glass windows.

These sprinklers were tested and listed by Underwriters Laboratories for their ability to maintain the integrity of a window assembly placed in a test furnace for a 2-hour period. The test is based upon gas flow into the furnace as required to achieve a temperature in the furnace in the absence of sprinklers matching the standard time-temperature curve in ASTM E119.

Where approved in accordance with Sections 104 of the International Building Code and International Fire Code, which in part authorizes the use of alternative materials and methods, Model WP Series Window Sprinklers may be used as interior protection of non-operable windows or glazing that are part of a fire resistance rated wall in sprinklered or non-sprinklered buildings. With the thermal operating elements removed, some of these sprinklers may also be used for outdoor exposure protection of non-operable windows or glazing when installed on a deluge system in accordance with NFPA requirements.

Model WP Series Window Protection Sprinklers are available in a variety of finishes (see Table F). Model WP56 sprinklers in white polyester, black polyester, or Electroless Nickel PTFE (ENT) finishes are cULus Listed as corrosion resistant sprinklers. The Model WP56SS (Stainless Steel) is cULus listed as corrosion resistant without any additional finish, but may be polyester coated for aesthetic reasons. In addition to the exposed versions of the product, the Model WP56C offers a flat plate concealed option.

Additional information

Dimensions 1.18 × 1.18 × 2.31 in
Manufacturer

Reliable Automatic Sprinkler Company

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Style

Pendent

K-Factor

5.6 (80 metric)

Max Working Pressure

250 psi (17.2 bar)

Finish

Poly White

Sensitivity

Fast Response

Temperature Rating

200°F (93°C)

Attributes

Dimensions 1.18 × 1.18 × 2.31 in
Manufacturer

Reliable Automatic Sprinkler Company

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Style

Pendent

K-Factor

5.6 (80 metric)

Max Working Pressure

250 psi (17.2 bar)

Finish

Poly White

Sensitivity

Fast Response

Temperature Rating

200°F (93°C)

Product Features

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/