Description
The S89 and S890 provide operating control and system shutdown on loss of main burner flame in direct ignition central heat furnaces and heating appliances with hot surface igniter.
Hot Surface Ignition Control, One Rod, 15/15 sec time
The S89 and S890 provide operating control and system shutdown on loss of main burner flame in direct ignition central heat furnaces and heating appliances with hot surface igniter.
The S89 and S890 provide operating control and system shutdown on loss of main burner flame in direct ignition central heat furnaces and heating appliances with hot surface igniter.
Weight | 0.7 lbs |
---|---|
Dimensions | 5.25 × 4.06 × 1.94 in |
Manufacturer | Honeywell |
Brand | Resideo |
Condition | New |
Unit of Measurement | PK (Pack) |
Production Status | Active |
Weight | 0.7 lbs |
---|---|
Dimensions | 5.25 × 4.06 × 1.94 in |
Manufacturer | Honeywell |
Brand | Resideo |
Condition | New |
Unit of Measurement | PK (Pack) |
Production Status | Active |
• S89G,H and S890G,H provide three tries for ignition before lockout, with 30 sec. min. purge before second and third tries.
• S89J and S890J provide 2 or 4 sec. (depending on model) max. ignition activation periods.
• S890 provides 30 sec. min. prepurge on initial trial for ignition.
• Compatible with Norton 201 and 271 or equivalent hot surface igniters.
• S89D,H and S890D,H require a separate sensor mounted on burner (Q354 recommended).
• Available with leadwires for line voltage connections.
• Available with Molex plug for connecting D80D Vent Damper.
• Modules can be used on either natural or LP gas; they provide 100 percent shutoff of gas on lockout.
• Modules have relay contacts for use with any direct ignition gas control with max. 2.0 A, 24 Vac rating.
• Modules use rectification principle for flame sensing.
• -40 °F to 175 °F [-40 °C to 79 °C) temperature rating.