Siemens FCM-6

$627.01

Fan-Control-Module Switches

Availability: In Stock
Condition: New
Brand: Siemens
Status: Active
SKU: 45568
Manufacturer Part #: FCM-6
Secondary Part #: 500-033140

Description

Designed for use in a Siemens Modular (or FireFinder XLS) fire-alarm control panel, Model FCM-6 is an option module that provides manual control of building HVAC system fans, motors, and dampers. Each FCM-6 module provides six (6) sets of three (3) push-button switches for manual system control. Each switch has three (3) associated LEDs to indicate Fan / Damper / Motor status: OFF (Red LED); ON (Green LED) and TROUBLE (Yellow LED). When in the automatic position, the red and green LEDs indicate Fan / Damper / Motor status (On or Off) based on the system logic that can be programmed to automatically control the fan outputs. When manually switched to the OFF position, the red LED will flash indicating that the output circuit used to turn off the Fan / Damper / Motor has activated. The red LED will light solid-red to indicate positive feedback of the Fan / Damper / Motor actually turning OFF (via a monitored input). When manually switched to the ON position, the green LED will flash indicating that the output circuit used to turn on the Fan / Damper / Motor has activated. The green LED will light solid green to indicate positive feedback of the Fan / Damper / Motor actually turning on (via a monitored input). During system reset when switches are turned manually to the ON or the OFF position their associated outputs do not change state. They stay either ON or OFF based on the switch’s position. Outputs will only change state when manually controlled via the ON / OFF switch or based on system logic when switch is in the Auto position. Each Model FCM-6 is mounted on a hinged panel as a part of the Siemens Modular (or FireFinder XLS) command-console enclosure. Any combination of a Model SCM-8, LCM-8 or a FCM-6 module may be mounted on a Model ID-MP. A six (6) conductor cable is supplied for interconnection of the modules. A 30-inch cable (CCL) is available for connection between rows. Models SCM-8, LCM-8, and FCM-6 can be remotely mounted up to 1000 feet (304.8 m.) from the main enclosure. Models REMBOX2 and REMBOX4 lobby enclosures are required for remote mounting of Model SCM-8, LCM-8 and FCM-6. A Model CSB sounder is optionally available for switch audible feedback for remote mounting applications.

Documents

Description

Designed for use in a Siemens Modular (or FireFinder XLS) fire-alarm control panel, Model FCM-6 is an option module that provides manual control of building HVAC system fans, motors, and dampers. Each FCM-6 module provides six (6) sets of three (3) push-button switches for manual system control. Each switch has three (3) associated LEDs to indicate Fan / Damper / Motor status: OFF (Red LED); ON (Green LED) and TROUBLE (Yellow LED). When in the automatic position, the red and green LEDs indicate Fan / Damper / Motor status (On or Off) based on the system logic that can be programmed to automatically control the fan outputs. When manually switched to the OFF position, the red LED will flash indicating that the output circuit used to turn off the Fan / Damper / Motor has activated. The red LED will light solid-red to indicate positive feedback of the Fan / Damper / Motor actually turning OFF (via a monitored input). When manually switched to the ON position, the green LED will flash indicating that the output circuit used to turn on the Fan / Damper / Motor has activated. The green LED will light solid green to indicate positive feedback of the Fan / Damper / Motor actually turning on (via a monitored input). During system reset when switches are turned manually to the ON or the OFF position their associated outputs do not change state. They stay either ON or OFF based on the switch’s position. Outputs will only change state when manually controlled via the ON / OFF switch or based on system logic when switch is in the Auto position. Each Model FCM-6 is mounted on a hinged panel as a part of the Siemens Modular (or FireFinder XLS) command-console enclosure. Any combination of a Model SCM-8, LCM-8 or a FCM-6 module may be mounted on a Model ID-MP. A six (6) conductor cable is supplied for interconnection of the modules. A 30-inch cable (CCL) is available for connection between rows. Models SCM-8, LCM-8, and FCM-6 can be remotely mounted up to 1000 feet (304.8 m.) from the main enclosure. Models REMBOX2 and REMBOX4 lobby enclosures are required for remote mounting of Model SCM-8, LCM-8 and FCM-6. A Model CSB sounder is optionally available for switch audible feedback for remote mounting applications.

Additional information

Weight 0.2 lbs
Manufacturer

Siemens Industry, Inc.

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Siemens FCM-6”

Cerberus® PRO Modular Switch-Control Module | LED-Control Module | Fan-Control Module

Download

Siemens - Data Sheet

Attributes

Weight 0.2 lbs
Manufacturer

Siemens Industry, Inc.

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Siemens FCM-6”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/