Siemens PAD-3R

$839.50

Distributed Power Module NAC Expander; up to 6A power supply

Availability: In Stock
Condition: New
Brand: Siemens
Status: Active
SKU: 72224
Manufacturer Part #: PAD-3R
Secondary Part #: 599-699190

Description

Designed for use with Siemens Building Technologies, Fire Safety Division fire alarm control panels, the PAD-3 is a Notification Appliance Circuit Expander with a built-in auxiliary power output. It is This power source is designed to provide the extra power required in buildings conforming to the Americans with Disabilities Act. The PAD-3 provides 6 amps of 24 VDC power for multiple uses. All 6 Amps can be directed to 4 Notification Appliance Circuits (NAC s). Each is rated at 3 A and is power limited. Either 1 or 2 inputs can control the four outputs. These outputs are compatible with all Fire Safety 24 VDC notification appliances. The PAD-3 can be configured so that the inputs can be programmed as steady outputs, ANSI temporal outputs, or synchronized strobe outputs. It can also be programmed so that one input will silence U-MHU Series horn/strobe horns while the strobes remain on using one set of wires. The PAD-3 also offers a 3 Amp auxiliary output for driving other portions of your fire alarm system such as door holders. This 24 VDC filtered output is power limited. When using this output, the total power available from the PAD-3 will not exceed 6 Amps. A trouble contact is provided for monitoring the PAD-3with a fire alarm panel through the input. It also has a Form C dry contact for trouble monitoring, allowing the user has the option of connecting it to a conventional fire alarm panel’s existing notification circuit, or controlling it with a TRI Series device on intelligent fire systems. The PAD-3 offers battery supervision and management as is required of fire alarm system components. Ground faults are transmitted as are any other trouble conditions. Trouble conditions not only change the state of the trouble contact in the unit, but they also break the notification circuit input to create a trouble signal in the fire alarm control unit. System 3 enclosures may also be used to house multiple PAD-3 modules in a single enclosure. Two modules are capable of sharing the same battery set when mounted in the same enclosure. UL, ULC Listed, CSFM, NYMEA and FM Approved. Red Enclosure.

Documents

Description

Designed for use with Siemens Building Technologies, Fire Safety Division fire alarm control panels, the PAD-3 is a Notification Appliance Circuit Expander with a built-in auxiliary power output. It is This power source is designed to provide the extra power required in buildings conforming to the Americans with Disabilities Act. The PAD-3 provides 6 amps of 24 VDC power for multiple uses. All 6 Amps can be directed to 4 Notification Appliance Circuits (NAC s). Each is rated at 3 A and is power limited. Either 1 or 2 inputs can control the four outputs. These outputs are compatible with all Fire Safety 24 VDC notification appliances. The PAD-3 can be configured so that the inputs can be programmed as steady outputs, ANSI temporal outputs, or synchronized strobe outputs. It can also be programmed so that one input will silence U-MHU Series horn/strobe horns while the strobes remain on using one set of wires. The PAD-3 also offers a 3 Amp auxiliary output for driving other portions of your fire alarm system such as door holders. This 24 VDC filtered output is power limited. When using this output, the total power available from the PAD-3 will not exceed 6 Amps. A trouble contact is provided for monitoring the PAD-3with a fire alarm panel through the input. It also has a Form C dry contact for trouble monitoring, allowing the user has the option of connecting it to a conventional fire alarm panel’s existing notification circuit, or controlling it with a TRI Series device on intelligent fire systems. The PAD-3 offers battery supervision and management as is required of fire alarm system components. Ground faults are transmitted as are any other trouble conditions. Trouble conditions not only change the state of the trouble contact in the unit, but they also break the notification circuit input to create a trouble signal in the fire alarm control unit. System 3 enclosures may also be used to house multiple PAD-3 modules in a single enclosure. Two modules are capable of sharing the same battery set when mounted in the same enclosure. UL, ULC Listed, CSFM, NYMEA and FM Approved. Red Enclosure.

Additional information

Weight 12 lbs
Manufacturer

Siemens Industry, Inc.

Brand

Condition

New

Unit of Measurement

EA (Each)

Type

NAC Extender, Power Supply

Color

Red

Production Status

Active

Reviews

There are no reviews yet.

Be the first to review “Siemens PAD-3R”

PAD-3 Distributed Power Supply Unit Notification Appliance Circuit

Download

Siemens - Data Sheet

Attributes

Weight 12 lbs
Manufacturer

Siemens Industry, Inc.

Brand

Condition

New

Unit of Measurement

EA (Each)

Type

NAC Extender, Power Supply

Color

Red

Production Status

Active

Product Features

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Siemens PAD-3R”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/