Silent Knight IFP-2000VIP

Voice Integration Panel with Analog / Addressable Fire Alarm Control

Availability: Please Call for Availability
Condition: New
Brand: Silent Knight
Status: Discontinued
SKU: 45189
Manufacturer Part #: IFP-2000VIP

Description

The IFP-2000VIP is an intelligent analog/addressable fire alarm control panel combined with an integrated single channel voice evacuation system. The basic IFP-2000VIP system has one onboard signal line circuit (SLC) loop which can support 159 IDP sensors and 159 IDP modules. The IFP-2000VIP has eight on-board FlexputTM circuits that can be configured for auxiliary power, notification outputs, or for conventional smoke detector inputs (Class A or Class B). The FACP also has a built-in, dual-line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert. The IFP-2000VIP supports a variety of devices, including RA-2000 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), RPS-1000 intelligent power module, and Intelligent Device Protocol (IDP) devices. The IFP-2000VIP places all of the critical user interface controls at the main panel. This seamless combination of fire detection and voice evacuation technology simplifies operation and programming of the entire system. The IFP-2000VIP system is scalable from 50 to 1000 watts using a distributed amplification scheme to provide the power to the appropriate areas for evacuation coverage.

Documents

Description

The IFP-2000VIP is an intelligent analog/addressable fire alarm control panel combined with an integrated single channel voice evacuation system. The basic IFP-2000VIP system has one onboard signal line circuit (SLC) loop which can support 159 IDP sensors and 159 IDP modules.

The IFP-2000VIP has eight on-board FlexputTM circuits that can be configured for auxiliary power, notification outputs, or for conventional smoke detector inputs (Class A or Class B). The FACP also has a built-in, dual-line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert.

The IFP-2000VIP supports a variety of devices, including RA-2000 remote annunciator, 5824 serial/parallel printer interface module (for printing system reports), RPS-1000 intelligent power module, and Intelligent Device Protocol (IDP) devices.

The IFP-2000VIP places all of the critical user interface controls at the main panel. This seamless combination of fire detection and voice evacuation technology simplifies operation and programming of the entire system. The IFP-2000VIP system is scalable from 50 to 1000 watts using a distributed amplification scheme to provide the power to the appropriate areas for evacuation coverage.

Additional information

Weight 16 lbs
Dimensions 4.6 × 20 × 26.5 in
Color

Red

Mounting

Flush, Surface

Series

Production Status

Discontinued

Brand

Reviews

There are no reviews yet.

Be the first to review “Silent Knight IFP-2000VIP”

Voice Integration Panel with Analog / Addressable Fire Alarm Control: IFP-2000VIP

Download

Silent Knight - Data Sheet

Attributes

Weight 16 lbs
Dimensions 4.6 × 20 × 26.5 in
Color

Red

Mounting

Flush, Surface

Series

Production Status

Discontinued

Brand

Product Features

  • Built-in support for up to 159 IDP sensors and 159 IDP modules, expandable to 636 points per IFP-2000 panel
  • All the features of the IFP-2000 Fire Alarm Control Panel combined with fully integrated voice evacuation system
  • Built-in Digital Message Repeater using DSP technology
  • Three field programmable user messages
  • Upload/download voice messages using a PC and the 7780 voice messaging application
  • Program voice messages via serial interface or built-in microphone
  • Support for up to eight VIP-50’s or VIP-125’s (SBUS addressable amplifiers) for a maximum of 1000 watts per system
  • Single enclosure for both fire and voice system control components
  • On-board supervised microphone
  • System can support two supervised remote microphones (VIP-RM2000s)
  • Up to 64 mappable speaker circuits using a combination of VIP-50s and VIP-CE4s
  • Supports 25 Vrms or 70-7 Vrms speaker circuits with VIP-50 only
  • Built-in Ethernet and USB interface for programming
  • Improvements in SKSS-2 delivers five times faster uploads/downloads
  • All call and Non-Alarm buttons to quickly select all active or all the non-active output groups
  • 999 software zones and 999 output groups
  • Jumpstart® auto-programming

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Silent Knight IFP-2000VIP”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/