Categories

Shop

Showing 24697–24708 of 77403 results

Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization
Mfr. Part #: MEP230H
SKU: 180109

$466.09

Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start, lockout on air flow open 10 seconds after the start of a cycle, selectable recycle/non-recycle lockout on air flow open after flame is proven and Dedicated Lockout after loss of flame
Mfr. Part #: MEP235
SKU: 180110

$413.05

Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start with additional 6 second igniter on time with main fuel. To be used with intermittent pilot only
Mfr. Part #: MEP236
SKU: 180111

$481.34

Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start. Ignition de-energized 3 seconds after pilot detected. Provides 8 second pilot stabilization period
Mfr. Part #: MEP238
SKU: 180112

$470.73

Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, prove open at start, and post purge (0 to 90 seconds)
Mfr. Part #: MEP290
SKU: 180113

$413.05

Placeholder
Same as MEP560 without pilot stabilization period. Will not lockout on air flow open during purge
Mfr. Part #: MEP536
SKU: 180114

$518.47

Placeholder
Same as MEP536 except provides one recycle on main flame fail
Mfr. Part #: MEP537
SKU: 180115

$518.47

Placeholder
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization, 10 sec main trial for ignition, run-check switch
Mfr. Part #: MEP560
SKU: 180116

$518.47

Placeholder
Programmer, Selectable recycle/non-recycle function, TFI timing, purge timing, post purge (30 sec max), prove open at start, 10 sec main trial for ignition, run-check switch
Mfr. Part #: MEP561
SKU: 180117

$518.47

Placeholder
Programmer, Selectable TFI timing, purge timing, post purge, prove open at start, 8 sec pilot stabilization, 10 sec main trial for ignition, with lockout on loss of air flow. Non-recycle, run-check switch
Mfr. Part #: MEP562
SKU: 180118

$518.47

Placeholder
Same as MEP560 except purge timings are 7 30, 60, and 240 (4 minutes) seconds
Mfr. Part #: MEP564
SKU: 180119

$518.47

Programmer, relight operation on main flame fail, lockout on PTFI and MTFI flame fail, 10 sec PTFI (fixed), 5 sec pilot proving, 5 sec MTFI
Mfr. Part #: MEP300
SKU: 180120

$205.53