Honeywell XLS140-2

SKU: 47275
Manufacturer Part #: XLS140-2
Condition: New
Brand: Honeywell
Status: Discontinued

Fire Alarm Control Panel

Availability: Please Call for Availability

Description

In stand-alone or network configurations, Honeywell’s XLS140-2 meets virtually every application requirement. Designed with modularity and for ease of system planning, the XLS140-2 can be configured with just a few devices for small building applications, or for a large campus or high-rise application. Simply add additional peripheral equipment to suit the application. The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line.

Documents

Description

In stand-alone or network configurations, Honeywell’s XLS140-2 meets virtually every application requirement.

Designed with modularity and for ease of system planning, the XLS140-2 can be configured with just a few devices for small building applications, or for a large campus or high-rise application. Simply add additional peripheral equipment to suit the application.

The FireWatch Series internet monitoring modules IPDACT-2 and IPDACT-2UD permit monitoring of alarm signals over the Internet, saving the monthly cost of two dedicated business telephone lines. Although not required, the secondary telephone line may be retained providing backup communication over the public switched telephone line.

Additional information

Weight 16 lbs
Manufacturer

Honeywell

Brand

Condition

New

Type

Control Panel

Style

Addressable

Color

N/A

Series

Production Status

Discontinued

Compatibility

Reviews

There are no reviews yet.

Be the first to review “Honeywell XLS140-2”

XLS140-2(E): Fire Alarm Control Panel

Download

Honeywell - Data Sheet

Attributes

Weight 16 lbs
Manufacturer

Honeywell

Brand

Condition

New

Type

Control Panel

Style

Addressable

Color

N/A

Series

Production Status

Discontinued

Compatibility

Product Features

  • Listed to UL Standard 864, 9th edition.
  • One, expandable to two, isolated intelligent Signaling Line Circuit (SLC) Style 4, 6 or 7.
  • Up to 159 detectors (any mix of ion, photo, thermal, or multi-sensor) and 159 modules (Addressable pull stations, normally open contact devices, two-wire smoke, notification, or relay) per SLC. 318 devices per loop/636 per FACP or network node.
  • Standard 80-character display, 640-character large display, or display-less (a node on a network).
  • Network options:
    • High-speed network for up to 200 nodes (XLS3000, XLS140-2, XLS140, XLS-NCA/-NCA2 Network Annunciator, or XLS-DVC).
    • Standard network for up to 103 nodes (XLS140, XLS140- 2, XLS3000, XLS-NCA/-NCA2 Network Annunciator, or XLS-DVC, and Honeywell Enterprise Buildings Integrator [EBI]). Up to 54 nodes when DVC is used in network paging.
  • 6.0 amp switch mode power supply with four Class A/B built-in Notification Appliance Circuits (NAC). Selectable System Sensor, Wheelock, or Gentex strobe synchronization.
  • Built-in Alarm, Trouble, Security, and Supervisory relays.
  • VeriFire® Tools online or offline programming utility. Upload/ Download, save, store, check, compare, and simulate panel databases. Upgrade panel firmware.
  • Autoprogramming and Walk Test reports.
  • Optional universal 636-point DACT.
  • 80-character remote annunciators (up to 32).
  • EIA-485 annunciators, including custom graphics.
  • Printer interface (80-column and 40-column printers).
  • History file with 800-event capacity in nonvolatile memory, plus separate 200-event alarm-only file.
  • Alarm Verification selection per point, with tally.
  • Autoprogramming and Walk Test reports.
  • Presignal/Positive Alarm Sequence (PAS).
  • Silence inhibit and Auto Silence timer options.
  • March time/temporal/California two-stage coding/strobe synchronization.
  • Field-programmable on panel or on PC, with VeriFire Tools program check, compare, simulate.
  • Full QWERTY keypad.
  • Battery charger supports 18 – 200 amp hour batteries.
  • Non-alarm points for lower priority functions.
  • Remote ACK/Signal Silence/System Reset/Drill via monitor modules.
  • Automatic time control functions, with holiday exceptions.
  • Surface Mount Technology (SMT) electronics.
  • Extensive, built-in transient protection.
  • Powerful Boolean logic equations.
  • Support for SCS Series smoke control system in HVAC mode.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Honeywell XLS140-2”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/