This product has been replaced by

Silent Knight IFP-100ECS

Emergency Communication System with Fire Alarm Control Panel

Manufacturer Part #: IFP-100ECS

Silent Knight IFP-100ECS

Emergency Communication System with Fire Alarm Control Panel

Availability: Please Call for Availability
Condition: New
Brand: Silent Knight
Status: Discontinued
SKU: 45423
Manufacturer Part #: IFP-100ECS

Description

The IFP-100ECS is an intelligent analog/addressable fire alarm control panel combined with an Emergency Communication System (ECS). When the ECS features are enabled, they are integrated with the fire alarm and voice evacuation functions of the control panel. The IFP-100ECS panel and accessories provide features to meet the requirements for Mass Notification Systems as described in UL 2572. The IFP-100ECS has four notification appliance circuits that can be programmed for notification outputs or auxiliary power. The FACP also has a built-in, dual-line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert. The IFP-100ECS supports a variety of devices, including RA-100 or RA-1000 remote annunciators, 5824 serial/parallel printer interface module (for printing system reports), 5496 or RPS-1000 intelligent power modules, and IDP or SD devices. The IFP-100ECS system is scalable from 50 to 1000 watts using a distributed amplification scheme to provide the power to the appropriate areas for evacuation coverage.

Documents

Description

The IFP-100ECS is an intelligent analog/addressable fire alarm control panel combined with an Emergency Communication System (ECS). When the ECS features are enabled, they are integrated with the fire alarm and voice evacuation functions of the control panel. The IFP-100ECS panel and accessories provide features to meet the requirements for Mass Notification Systems as described in UL 2572.

The IFP-100ECS has four notification appliance circuits that can be programmed for notification outputs or auxiliary power. The FACP also has a built-in, dual-line digital fire communicator, Form C trouble relay, and two programmable Form C relays. The firmware has powerful features such as detector sensitivity, day/night thresholds, drift compensation, pre-trouble maintenance alert, and calibration trouble alert.

The IFP-100ECS supports a variety of devices, including RA-100 or RA-1000 remote annunciators, 5824 serial/parallel printer interface module (for printing system reports), 5496 or RPS-1000 intelligent power modules, and IDP or SD devices.

The IFP-100ECS system is scalable from 50 to 1000 watts using a distributed amplification scheme to provide the power to the appropriate areas for evacuation coverage.

Additional information

Weight 16 lbs
Dimensions 4.75 × 20 × 26.50 in
Color

Red

Series

Brand

Production Status

Discontinued

Reviews

There are no reviews yet.

Be the first to review “Silent Knight IFP-100ECS”

Silent Knight IFP-100ECS Data Sheet

Download

Farenhyt - Data Sheet

Attributes

Weight 16 lbs
Dimensions 4.75 × 20 × 26.50 in
Color

Red

Series

Brand

Production Status

Discontinued

Product Features

  • 15 Recordable one minute messages that can be mapped to eight ECS buttons.
  • Can select ECS message as priority over fire.
  • Support of up to seven ECS-RCU’s. The ECS-RCU meets the requirements for a LOC.
  • Programmable trigger inputs from an external source, such as a Monaco system, to either the VCM, RVM, or 5880. Up to eight inputs available on the 5880 module.
  • Built-in support for up to 99 IDP detectors and 99 IDP modules or 127 SD devices.
  • All the features of the IFP-100 Fire Alarm Control Panel combined with an emergency communication system.
  • Support for up to eight ECS-50W’s, ECS–125W’s, or ECS-DUAL-50W’s (SBUS addressable amplifiers) for a maximum of 1000 watts per system.
  • Single enclosure for both fire and emergency control system components.
  • On-board supervised microphone.
  • Up to 64 mappable speaker circuits using a combination of ECS-50W / 125W’s and ECS-CE4’s mappable to 40 buttons controlling selected output groups.
  • Supports 25 Vrms or 70.7 Vrms speaker circuits using ECS-50W’s.
  • UL listed for 250Hz signaling with ECS-DUAL50W and compatible speakers.
  • Built-in RS-232 and USB interface for programming.
  • All call and Non-Active Call buttons to quickly select all active or all the non-active output groups.

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Silent Knight IFP-100ECS”

You may also like...

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/