Description

The IFP-300ECS (red) and IFP-300ECSB (black) are Intelligent analog/ addressable fire alarm control panels (FACP) combined with an Emergency Communication System (ECS). When the ECS features are enabled, they are integrated with the fire alarm and voice evacuation functions of the control panel. The IFP-300ECS panel and accessories provide features to meet the requirements for Mass Notification Systems as described in UL 2572. This state of the art fire alarm control panel allows you to choose one of three SLC protocols per system. The basic IFP-300ECS panel contains one built in signaling line circuit (SLC), which can support 159 System Sensor® IDP/SK sensors and 159 IDP/SK modules or 127 (SD) Hochiki® devices per loop. Additional SLC loops can be added using the model 6815 SLC expander for IDP/SK devices to increase the overall point capacity to a maximum of 300 points per panel, or model 5815XL SLC Expander for SD devices to increase the overall point capacity to a maximum of 254 points per panel. IFP-300ECS has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. A separate network can be used for voice paging across all panels. The IFP-300ECS supports a variety of devices, including RA-2000, RA-1000 or RA-100 remote annunciator, 5824 serial parallel printer interface module (for printing system reports), RPS-1000 power module, and IDP, SK or SD devices.

Documents

Description

The IFP-300ECS (red) and IFP-300ECSB (black) are Intelligent analog/ addressable fire alarm control panels (FACP) combined with an Emergency Communication System (ECS). When the ECS features are enabled, they are integrated with the fire alarm and voice evacuation functions of the control panel. The IFP-300ECS panel and accessories provide features to meet the requirements for Mass Notification Systems as described in UL 2572.

This state of the art fire alarm control panel allows you to choose one of three SLC protocols per system. The basic IFP-300ECS panel contains one built in signaling line circuit (SLC), which can support 159 System Sensor® IDP/SK sensors and 159 IDP/SK modules or 127 (SD) Hochiki® devices per loop. Additional SLC loops can be added using the model 6815 SLC expander for IDP/SK devices to increase the overall point capacity to a maximum of 300 points per panel, or model 5815XL SLC Expander for SD devices to increase the overall point capacity to a maximum of 254 points per panel.

IFP-300ECS has the interconnection capability for up to 32 panels. The system has two modes of operation, multiple panels covering one larger building, or multiple independent buildings. A separate network can be used for voice paging across all panels.

The IFP-300ECS supports a variety of devices, including RA-2000, RA-1000 or RA-100 remote annunciator, 5824 serial parallel printer interface module (for printing system reports), RPS-1000 power module, and IDP, SK or SD devices.

Additional information

Weight 16 lbs
Dimensions 28.10 × 21.59 × 5.10 in
Manufacturer

Honeywell

Brand

Condition

New

Type

Control Panel

Style

Addressable

Color

Red

Series

Production Status

Active

Compatibility

N/A

Reviews

There are no reviews yet.

Be the first to review “Silent Knight IFP-300ECS”

IFP-300ECS / IDP-300ECSB: Emergency Communication System with Fire Alarm Control Panel

Download

Silent Knight - Data Sheet

Attributes

Weight 16 lbs
Dimensions 28.10 × 21.59 × 5.10 in
Manufacturer

Honeywell

Brand

Condition

New

Type

Control Panel

Style

Addressable

Color

Red

Series

Production Status

Active

Compatibility

N/A

Product Features

  • Single enclosure for both Fire and Emergency Control System components
  • Can select ECS message as priority over fire
  • Built-in support for up to 159 IDP/SK detectors and 159 IDP/SK modules or 127 SD SLC devices
  • Four line LCD display with 40 characters per line
  • On-board supervised microphone
  • Available in a red or black cabinet
  • Separate network support for voice paging
  • Built-in USB interface for programming
  • Built-in dual phone line, digital alarm communicator/ transmitter (DACT), IP or optional cellular technologies
  • JumpStart AutoProgramming® feature for easy programming
  • Capable of producing 520 Hz tones to meet NFPA 72 requirements
  • 15 Recordable one minute messages that can be mapped to eight ECS buttons
  • Firmware can be upgraded in the field
  • Supports up to four SWIFT wireless gateways. Each gateway can have up to 49 wireless devices
  • Support for up to eight SBUS addressable amplifiers using a combination of ECS-50W, ECS-125W, ECS-INT50W or ECS-DUAL50W for a maximum of 1000 watts per system
  • Supports up to seven ECS-LOC’s
  • Network support for up to 32 Sites

What's Included

Shipping Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Return Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Silent Knight IFP-300ECS”

Pricing & Availability Details

Pricing & Lead Times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.

Payment Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290.

Return & Cancellation Details

Equipment must be returned within (30) days of the date it was shipped, or made ready for pickup. In order to initiate a return, you must contact our sales team via email at [email protected] to receive an RMA # if it meets all criteria. Products returned after (30) days from our shipment date will be refused. After RMA acceptance, any parts that are returned to FireAlarm.com are subject to a minimum 25% restocking fee. New parts must be returned with original packaging, in un-opened, and uninstalled condition. If not, these parts may be subject to increased restocking fees or refusal. Depending on the circumstances of your order, and if you are a long-time customer of FireAlarm.com, other arrangements can be made. See our complete return policy for more information at: https://firealarm.com/faq/