Vesda VLS-214

VLS detector with a centrally mounted LCD Programmer module and a Scanner Display module. 7 relays version.

Availability: Please call for availability
Condition: New
Brand: Vesda
Status: Obsolete
SKU: 45813
Manufacturer Part #: VLS-214
Replacement: VES-A10-P

Description

The VESDA VLS is similar to the standard VESDA VLP detector, but also includes a valve mechanism in the inlet manifold and software to control the airflow from the four sectors (pipes). This configuration enables a single VESDA zone to be divided into four separate sectors, for example, distinguishing between separate voids within a room. The VLS draws air from all sectors in use. If the smoke level reaches the Adaptive Scan Threshold, the VLS quickly scans each pipe to identify which pipe is carrying smoke. If more than one pipe is transporting smoke, the sector with the highest smoke concentration is designated as the First Alarm Sector (FAS). Once Fast Scan is completed and the FAS identified, the VLS continues to closely monitor all four sectors (pipes) to monitor fire growth and maintain full protection of the area. There are four alarm levels (Alert, Action, Fire 1 and Fire 2) for each sector (pipe) and the sensitivity for each alarm level can be set to ensure the optimum alarm thresholds are applied for each sector.

Documents

Description

The VESDA VLS is similar to the standard VESDA VLP detector, but also includes a valve mechanism in the inlet manifold and software to control the airflow from the four sectors (pipes). This configuration enables a single VESDA zone to be divided into four separate sectors, for example, distinguishing between separate voids within a room.

The VLS draws air from all sectors in use. If the smoke level reaches the Adaptive Scan Threshold, the VLS quickly scans each pipe to identify which pipe is carrying smoke. If more than one pipe is transporting smoke, the sector with the highest smoke concentration is designated as the First Alarm Sector (FAS).

Once Fast Scan is completed and the FAS identified, the VLS continues to closely monitor all four sectors (pipes) to monitor fire growth and maintain full protection of the area.

There are four alarm levels (Alert, Action, Fire 1 and Fire 2) for each sector (pipe) and the sensitivity for each alarm level can be set to ensure the optimum alarm thresholds are applied for each sector.

Additional information

Weight 9 lbs
Dimensions 4.9 × 8.9 × 13.8 in
Manufacturer

Honeywell International

Brand

Condition

New

Unit of Measurement

EA (Each)

Series

Production Status

Obsolete

Reviews

There are no reviews yet.

Be the first to review “Vesda VLS-214”

VESDA VLS

Download

Vesda – Data Sheet

VESDA VLS End of Life (EOL) Notice

Download

Vesda – Product Bulletin

Attributes

Weight 9 lbs
Dimensions 4.9 × 8.9 × 13.8 in
Manufacturer

Honeywell International

Brand

Condition

New

Unit of Measurement

EA (Each)

Series

Production Status

Obsolete

Product Features

  • Individual pipe identification
  • Adaptive Scan Threshold
  • Wide sensitivity range
  • Laser based smoke detection
  • VESDAnet communication
  • 4 alarm levels per sector
  • High efficiency aspirator
  • Clean air barrier optics protection
  • Easy to replace air filter
  • 7 or 12 programmable relays option
  • AutoLearn
  • Referencing
  • Event log
  • Recessed mounting

What's Included

Shipping Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290. All orders are subject to processing time into our main shipment hub.  After placing your order, you will be sent your shipment tracking number after the mandatory processing has been completed.

Return Details

This item must be returned within (30) days of the date it was purchased, shipped, delivered, or made ready for pickup. Refunds and returns must be sent via email to [email protected]. Please outline the items being returned, the reason for the return, along with any pictures of additional information about the product. See our complete return policy for more information at: https://firealarm.com/faq/

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Reviews

There are no reviews yet.

Be the first to review “Vesda VLS-214”

Shipping Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), via Apple or Google Pay, or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290. All orders are subject to processing time into our main shipment hub.  After placing your order, you will be sent your shipment tracking number after the mandatory processing has been completed.

Return Details

This item must be returned within (30) days of the date it was purchased, shipped, delivered, or made ready for pickup. Refunds and returns must be sent via email to [email protected]. Please outline the items being returned, the reason for the return, along with any pictures of additional information about the product. See our complete return policy for more information at: https://firealarm.com/faq/

Pricing & Availability Details

Lead times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. Product availability and pricing may change depending on market conditions. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.