Description

The XNX Universal Transmitter is a comprehensive gas detection system designed to operate in hazardous locations1 and utilize multiple sensor technologies, catalytic bead, electrochemical (EC), or infrared (IR) to detect toxic gases, flammable gases, and oxygen depletion gas hazards. Each technology has a dedicated personality board. Catalytic bead technology is used with the XNX mV personality board. Catalytic bead sensors respond to a wide variety of combustibles so are typically used for flammable gas detection. Electrochemical technology is used with the XNX electrochemical board. EC sensors measure toxic gases in low concentrations. The XNX EC sensors employ the patented Reflex™ cell fault diagnosis routine. Reflex™ checks for cell presence, cell dry-out, and cell open or short circuit. Reflex™ is automatically initiated by the transmitter at eight-hour intervals. It is also initiated on power up or sensor exchange. In the event of a cell failing this test, a sensor fault code is displayed. Reflex™ diagnostics occur in the first minutes of the power up sequence.

Documents

Description

The XNX Universal Transmitter is a comprehensive gas detection system designed to operate in hazardous locations1 and utilize multiple sensor technologies, catalytic bead, electrochemical (EC), or infrared (IR) to detect toxic gases, flammable gases, and oxygen depletion gas hazards. Each technology has a dedicated personality board. Catalytic bead technology is used with the XNX mV personality board. Catalytic bead sensors respond to a wide variety of combustibles so are typically used for flammable gas detection. Electrochemical technology is used with the XNX electrochemical board. EC sensors measure toxic gases in low concentrations. The XNX EC sensors employ the patented Reflex™ cell fault diagnosis routine. Reflex™ checks for cell presence, cell dry-out, and cell open or short circuit. Reflex™ is automatically initiated by the transmitter at eight-hour intervals. It is also initiated on power up or sensor exchange. In the event of a cell failing this test, a sensor fault code is displayed. Reflex™ diagnostics occur in the first minutes of the power up sequence.

Additional information

Weight 0.1 lbs
Manufacturer

Honeywell

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

XNX ® Universal Transmitter

Download

Honeywell - Data Sheet

Attributes

Weight 0.1 lbs
Manufacturer

Honeywell

Brand

Condition

New

Unit of Measurement

EA (Each)

Production Status

Active

Product Features

What's Included

Shipping Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290. All orders are subject to processing time at our main shipment hub.  After placing your order, you will be sent your shipment tracking number after the mandatory processing has been completed.

Return Details

This item must be returned within 45 days of the date it was purchased, shipped, delivered, or made ready for pickup. Refunds and returns must be sent via email to [email protected]. Please outline the items being returned, the reason for the return, along with any pictures of additional information about the product. See the return policy for complete information.

Testimonials

Rick A.
Dallas, TXI
Read More
"Great service. I received help with exactly what I needed and I received it all in a timely manner."
Charles O.
New Brunswick, NJ
Read More
"I had a big engineering/logistics issue that William over at FireAlarm.com helped me with. I don’t know what I would’ve done without their help!"
Jason G.
Los Angeles, CA
Read More
"The fastest delivery I’ve seen. Needed overnight emergency parts and I got just that."
Julia S.
Tampa, FL
Read More
"Needed last-minute maintenance done on my building’s system, and FireAlarm.com exceeded my expectations with how quickly it was done."

Leave a review

Shipping Details

You may remit payment via a US-Based Credit Card (CC Authorization Form), Wire Transfer (w/ $30 or $50 fee added to invoice), via PayPal (Or PayPal Pay Later), or by mailing us a check. You can also call in with your credit card information at any time: 888-497-0290. All orders are subject to processing time at our main shipment hub.  After placing your order, you will be sent your shipment tracking number after the mandatory processing has been completed.

Return Details

This item must be returned within 45 days of the date it was purchased, shipped, delivered, or made ready for pickup. Refunds and returns must be sent via email to [email protected]. Please outline the items being returned, the reason for the return, along with any pictures of additional information about the product. See the return policy for complete information.

Pricing & Availability Details

Lead times are based on details provided directly by the manufacturer, our network of distributors and based on historical lead times on any given product. This is the most up-to-date information we have currently. Product availability and pricing may change depending on market conditions. All orders are subject to 1 – 5 days of processing as the units must go through our product verification process at our main Shipping Hub in New York prior to being shipped out to you. Depending on your circumstances, we can expedite this processing time for additional costs, but orders cannot be expedited unless they are currently in stock. PLEASE NOTE: Any and all pricing and availability are subject to change without notice being given to the client.