Simplex 2975-9227

NEMA 1 red mounting box; required for 4090-9005

Note: Included with model 4090-9006

    Brand: Simplex FireAlarm.com Part #: 46719 Categories: , Manufacturer Part #: 2975-9227

    Description

    When combined with Suppression Release Peripherals, the 4100ES series fire alarm control panel provides actuator supervision and control for use in automatic extinguishing, and deluge or preaction releasing systems. Hazard area initiating and notification devices are controlled using either conventional or addressable circuits per standard 4100ES capabilities. The necessary releasing system logic is implemented within the 4100ES control panel as required for the local application.

    Information

    Weight 1.00 lbs
    Color

    Marking

    Brand

    Features

    Releasing control using the Simplex® 4100ES (or 4100U) Fire Alarm Control Panel to provide:

    • Coverage for multiple areas of Automatic Extinguishing
      Release and/or Deluge and Preaction Sprinkler System
      Release including audible escalation of events
    • Control of compatible Listed/Approved valves and actuators
    • Releasing appliance circuits (RACs) by connecting Notification appliance circuits (NACs) to Suppression Release Peripherals for actuator supervision and control

    Audible Escalation of Events:

    • Temporal or 20 bpm March Time pattern for first cross-zone alarm
    • 120 bpm March Time pattern to indicate releasing timer active
    • On steady to indicate releasing timer expired and actuator is activated
    • NOTE: Requires NACs dedicated to conventional horn control (not SmartSync operation) with strobes controlled on separate NACs

    4090-9005/-9006 Suppression Release Peripheral (SRP) with Dual Command Control:

    • Dual command control requires that both IDNet communications commands and an activated NAC are present to initiate the desired release
    • NAC provides wiring supervision to the actuator including monitoring of coil continuity and short circuit supervision to the coil supervision module

    Suppression Release Peripheral control features:

    • An on-board DC-DC regulator compensates for voltage drops to the peripheral and ensures proper control circuit voltage over a wide operating range
    • Provides a single RAC for control of actuators for up to 2 A using a 3 A NAC input (1 A using a 2 A NAC input)

    Related system components:

    • 4100ES Series control panel with Releasing Appliqué
    • Dedicated NAC output from 4100ES (or compatible NAC Extender)
    • Coil supervision module, one per RAC
    • Maintenance Switch, one per RAC
    • Abort Switch connected via an addressable interface module

    Resources

    4100ES Fire Control Panels: Automatic Extinguishing, Deluge and Preaction Sprinkler System Releasing Control
    Releasing System Peripherals: Fire Suppression System Abort Switches and Releasing Appliance Circuit (RAC) Maintenance Switches